1 GENERAL
RELATED SECTIONS
Spec Note: List appropriate Sections for related work specific
to project. Modify header/footer as applicable.
.1 Section 15[ ] 16[ ]:
Floor access covers, drains.
1.2 REFERENCES
.1 CSA A126.4, Rubber Floor Tile.
.2 ASTM C 501, Taber Abrasion.
.3 ASTM C 1028, Co-Efficient of Friction.
.4 ASTM D395, Rubber Property Compression Set Method B.
.5 ASTM D412, Rubber Properties in Tension.
.6 ASTM D 570, Moisture Absorption.
.7 ASTM D624, Test Method for Rubber Properties.
.8 ASTM D2240, Rubber Property Durometer Hardness.
.9 ASTM E648-03, Critical Radiant Flux.
.10 ASTM F970-00, Static Load Limit
1.3 SUBMITTALS
.1 Submit samples in accordance with Section [ ]
- [ ].
.2 Submit duplicate 300 x 300 mm sample pieces of sheet material.
.3 Submit Material Safety Data Sheets for installation adhesives,
cleaners and sealers.
.4 Submit layout drawing of flooring [tiles] [sheets] to [Owner]
[Consultant] [Engineer] for review prior to starting any work.
1.4 CLOSEOUT SUBMITTALS
.1 Provide maintenance data for resilient flooring for incorporation
into maintenance manual specified in Section [ ] – [ ].
1.5 EXTRA MATERIALS
.1 Provide extra materials of resilient sheet flooring and adhesives
in accordance with Section [ ] – [ ].
.2 Provide [ ] m2, [ %] of
each [colour], [pattern] and [type] of flooring material required
for project for maintenance use.
.3 Extra materials to be in one piece and from same production
run as installed materials.
.4 Clearly identify each type of sheet flooring and each container
of adhesive.
.5 Deliver to [Owner] [Engineer] [Consultant], upon completion
of the work of this section.
.6 Store where directed by [Owner] [Engineer] [Consultant].
delivery, storage and handling
.1 Deliver flooring materials undamaged with manufacturer's labels
intact.
.2 Store flooring materials in a protected area on site a minimum
of 24 hours prior to installation.
.3 Store rubber flooring materials flat, blocked off floor.
.4 Prevent damage or contamination to flooring materials from
water, moisture, freezing, excessive heat, direct sunlight and
construction dust or dirt.
.5 Protect flooring materials from construction activities. Provide
tarpaulins or plastic coverings blocked to allow ventilation and
prevent contamination from dust or debris.
1.7 ENVIRONMENTAL REQUIREMENTS
.1 Maintain air temperature and structural base temperature at
flooring installation area above 15 degrees C and below 30 degrees
C for 48 hours before, during and 72 hours after installation.
.2 Maintain a maximum relative humidity of 65% before, during
and for 72 hours after installation.
WARRANTY
.1 Supply manufacturer's standard limited warranty against defects
in materials or workmanship for [5 years for [Starlight] [Décor]
Sport Floor] [2 years for Classic Mat Sport Floor] from date of
purchase.
.2 Supply manufacturer's standard limited warranty against wear
exceeding 1% per year when recommended installation and maintenance
guidelines are followed.
PRODUCTS
2.1 MATERIALS
Spec Note: Select appropriate product(s) and/or options listed
in brackets
.1 Rubber Flooring Tile:
.1 Wearing Surface: 100% recycled vulcanized rubber throughout.
.2 Size: 1 219 mm x 1 829 mm mats.
.3 Colour: Black.
.4 Thickness: [10 mm] [12 mm] [19 mm].
.5 Texture: [Smooth] [Recessed checkerplate].
.6 Options: Interlocking format for non-adhesive installation.
.7 Material Properties:
.1 Shore Hardness: ASTM 2240, 60.
.2 Compression Set: ASTM D395, 2.40%.
.3 Taber Abrasion: ASTM C501, 247.6 (0.356 g weight loss).
.4 Tensile Strength: ASTM D412, 414.5 psi.
.5 Co-Efficient of Friction: ASTM C1028, 1.25 dry, 1.01 wet.
.6 Elongation at Break: ASTM D412, 193.4%.
.7 Tear Resistance: ASTM D624, 156 lbs/in.
.8 Moisture Absorption: ASTM D570, 0.13%.
.9 Static Load Limit: ASTM F970-00, .006
.8 Acceptable product: SportFloor Classic Mat Series as manufactured
by North West Rubber 33850 Industrial Avenue Abbotsford, B.C. Canada
V2S 7T9 Phone 1-800-663-8724 Fax 1-604-859-2009
E-mail sweets@northwestrubber.com
.2 Speckled Coloured Rubber Flooring:
.1 Wearing Surface: 100% recycled rubber with 20% EPDM colour
granules throughout.
.2 Size: 1 219 mm x 9 144 mm length rolls.
.3 Colour: [Mars Red] [Mercury Grey] [ Neptune Blue] [Venus Green]
[Earth Mixed] [Galaxy Mixed].
.4 Thickness: 9.5 mm.
.5 Texture: Smooth non-slip.
.6 Options: Interlocking format for non-adhesive installation.
.7 Material Properties:
.1 Shore Hardness: ASTM 2240, 65.
.2 Compression Set: ASTM D395, 9.5%.
.3 Taber Abrasion: ASTM C501, 170.5 (0.517 g weight loss).
.4 Tensile Strength: ASTM D412, 205.6 psi.
.5 Co-Efficient of Friction: ASTM C1028, 1.02 dry, 0.86 wet.
.6 Elongation at Break: ASTM D412, 205.6%.
.7 Tear Resistance: ASTM D624, 60 lbs/in.
.8 Moisture Absorption: ASTM D570, 1.3%.
.9 Static Load Limit: ASTM F970-00, .006
.8 Acceptable product: SportFloor Starlight Roll Series as manufactured
for North West Rubber 33850 Industrial Avenue Abbotsford, B.C.
Canada V2S 7T9 Phone 1-800-663-8724 Fax 1-604-859-2009
E-mail sweets@northwestrubber.com
.3 Solid Coloured Rubber Flooring Tile:
.1 Wearing Surface: 1.5 mm virgin rubber. .2 Size: 900 mm x 900
mm. .3 Backing: 100% SBR black rubber.
.4 Pattern: Marbleized.
.5 Finish: Textured non-slip.
.6 Thickness: 10 mm.
.7 Options: Interlocking format for non-adhesive installation.
.8 Colour:
.1 Solid: [Dark Grey with black] [Light Grey with black], [Red
with black] [Black with tan] [Dark Blue with tan] [Forest Green
with tan] [Chocolate with tan] [Mocha with tan] [Purple with tan]
[color [indicated] [selected by [Engineer] [Consultant].
.2 TriColour Swirl: [Rainbow – black with mixed] [Earthtone – black
with mixed] [colour [indicated] [selected by [Engineer] [Consultant].
.9 Material Properties:
.1 Shore Hardness: ASTM 2240, 84 (top) 75 (bot)
.2 Compression
Set: ASTM D395, 19.4%.
.3 Taber Abrasion: ASTM C501, 73.69 (.256 g weight loss).
.4 Tensile Strength: ASTM
D412, Top 1100 psi, Bottom 975.9 psi.
.5 Co-Efficient of Friction:
ASTM C1028, 0.93 dry, 0.84 wet.
.6 Elongation at Break: ASTM
D412, 398.0 %.
.7 Tear Resistance: ASTM D624, 155 lbs/in.
.8 Moisture Absorption: ASTM D570, 0.37%.
.9 Critical Radiant Flux: ASTM E648-03, 0.92.
.10 Static Load Limit: ASTM F970-00, .006
.10 Acceptable product: SportFloor Decor tiles as manufactured
for North West Rubber 33850 Industrial Avenue Abbotsford, BC. Canada
V2S 7T9 Phone 1-800-663-8724 Fax 1-604-859-2009
E-mail sweets@northwestrubber.com
ACCESSORIES
.1 Bevelled Edging: Black rubber transition ramp edging as available
from flooring manufacturer.
.2 Floor Filler: Cement based leveling compound. Acceptable product,
Mapei Planipatch, Planipatch-Plus or acceptable substitution.
.3 Adhesive: Single component or 2-part, SportFLOOR Adhesive,
a solvent free urethane adhesive as recommended by manufacturer
for dry conditions.
.4 Initial Cleaner (if required): Alkaline floor finish stripper
diluted 10:1 with clean water. Recommended product, Buckeye-Revelation
# 5032.
.5 Sealer (if required):
.1 SFS sealer for black rubber flooring tile.
.2 SFSG sealer for coloured rubber flooring tile.
.6 Maintenance Cleaner: PH neutral cleaner.
3 EXECUTION
SITE VERIFICATION OF CONDITIONS
.1 Examine floor areas to be covered and report any deficiencies
to the Contractor. Do not proceed with installation until substrates
and conditions comply with manufacturer's requirements for installation.
.2 Ensure floor substrate is clean and dry by using test methods
recommended by flooring manufacturer.
.3 Ensure building area and materials for flooring application
is maintained at minimum 15 degrees C, maximum 30 degrees C and
at maximum 65 % relative humidity for minimum 48 hours before installation,
during installation and for minimum 72 hours after completion of
work.
.4 Provide ventilation to installation area during installation
and for minimum 72 hours after completion of work.
Spec Note: Select appropriate substrate preparation
3.2 WOOD FLOOR PREPARATION
.1 Ensure wood subfloor material is CDX exterior plywood installed
smooth side up.
.2 Caulk all nail, staple or screw fasteners and seal with epoxy
sealant.
.3 Acclimatize subfloor for minimum 48 hours before installation
of flooring tile.
.4 Ensure subfloor is clean, dry and free of dust, dirt and any
contaminants and previous floor finishes.
.5 Patch cracks, holes and rough or uneven areas with manufacturer's
recommended cement based leveling compound.
CONCRETE FLOOR PREPARATION
.1 Ensure subfloor is smooth and level to a tolerance of 3 mm
in 1.8 m.
.2 Ensure concrete floors have cured for minimum 6 weeks.
.3 Perform moisture test recommended by flooring manufacturer
on concrete floor.
.a Poly File Test: Tape a sheet of plastic over a section of the
concrete floor. Wait for 72 hours. Check for moisture droplets
under the plastic sheet.
.b Calcium Chloride Test: Perform quantitative test, maximum 1.36
kg moisture emissions per 24 hours per 93 m2.
.4 Seal new concrete floors.
.5 Ensure existing concrete floors are clean, dry and smooth.
.6 Remove any wax, paint, varnish, adhesive or any other material
that would prevent proper bonding of adhesive.
.7 Repair any low spots with a cementitous based latex patch mix.
.8 Seal concrete that is rough or porous.
APPLICATION: FLOORING
.1 Ensure back of rubber flooring has been sanded to remove mold
release. (if required).
.2 Apply adhesive uniformly using recommended trowel and application
rate. Ensure a minimum 85% transfer from the floor to backing of
flooring.
.3 Do not spread more adhesive than can be covered by flooring
before initial set takes place.
.4 Lay flooring in a point to point installation with [colour
swirls orientated in the same direction] [with colour swirls orientated
in alternating directions]. Lay out to produce a minimum number
of seams. Border widths minimum 1/3 width of full material.
.5 Adjoin factory edge to factory edge of tiles. Install cut edge
of tiles along walls or vertical surfaces.
.6 Ensure joints are tight. Eliminate joints opening up between
tiles by taping tile corners together with masking tape.
.7 Lay tiles in small sections and roll with a 45 kg sectional
roller within 15 minutes of laying to ensure proper adhesive contact.
.8 Cut tiles neatly around fixed objects, and to fit irregular
and fill-in spaces using a sharp utility knife. Make repeated passes
when cutting to ensure straight cuts.
.9 Continue flooring through areas to receive movable type partitions
without interrupting floor pattern.
.10 Terminate flooring at centreline of door in openings where
adjacent floor finish or colour is dissimilar.
.11 Install beveled transition edge strips at unprotected or exposed
edges where flooring terminates.
.12 Promptly clean adhesive from top surface of tiles using a
soft cloth soaked in denatured alcohol.
.13 Prevent traffic on flooring for minimum 24 hours after installation.
3.5 CLEANING AND MAINTENANCE
.1 Initial Cleaning:
.1 Wait 48 hours after installation before proceeding with cleaning.
.2 Sweep tiles to remove all loose dirt and debris.
.3 Ensure petroleum based cleaners are not used.
.4 If required to remove mold release:
Work in small areas of floor at a time
Apply a recommended floor finish stripper diluted
with water using a mop. Leave mix on floor for 5 to 7 minutes.
Scrub wet floor using a rotary buffing machine equipped
with a medium ‘Scotch Brite' pad.
Remove wet residue using a wet-dry vacuum
Mop rinse floor with clean water and repeat removal
and drying method.
Repeat cleaning operations as required to remove
any remaining mold release or sediment.
Prohibit foot traffic on flooring until area is dry.
.2 Floor Finishing (if required): Complete id required in
project
.1 Install sealer by flooring manufacturer according to instructions
and application rate recommended by manufacturer.
.3 Regular Cleaning:
.1 Clean flooring on a regular basis using a PH neutral cleaner.
3.6 PROTECTION
.1 Protect new floors from [time of final set of adhesive] [after
initial sealing] until final inspection.
.2 Prohibit traffic on floor for 24 hours after installation.
.3 Provide ventilation to installation area during installation
and for minimum 72 hours after completion of work.
.4 Do not wash flooring for minimum 14 days after completion of
installation.
End of Section |